Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller
Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller

Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller

Price 30000 INR/ Piece

MOQ : 1 Piece

Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller Specification

  • Phase
  • Single Phase
  • Humidity
  • 0% to 95% RH, non-condensing
  • Protection Level
  • Not specified (typically indoor use)
  • Frequency
  • 50/60 Hz
  • Mounting Type
  • Panel/DIN rail mounting
  • Operating Temperature
  • 0C to 50C (32F to 122F)
  • Rated Voltage
  • 24 VAC
  • Main Material
  • PCB with electronic components, plastic enclosure
  • Processing Type
  • Digital Control
  • Condition
  • Used / Refurbished
  • Function
  • Controls VAV boxes and compatible actuators/sensors; monitors and regulates air flow
  • Application
  • Variable Air Volume (VAV) control in HVAC systems
  • Dimension (L*W*H)
  • Approx. 19 cm x 13 cm x 4.5 cm (7.5 in x 5.1 in x 1.77 in)
  • Power Mode
  • AC Powered
  • Voltage
  • 24 VAC 15%, 50/60 Hz
  • Power Consumption
  • 6 VA maximum at 24 VAC
  • Battery Life
  • Not applicable (AC powered device)
  • Status Indicators
  • Onboard status LEDs for power and communication
  • Enclosure Type
  • Open style, for mounting in control panel
  • Inputs
  • Up to 8 universal (analog/digital) inputs
  • Communication Protocol
  • Metasys N2 Bus
  • Compatible Sensors
  • Supports analog inputs (e.g., temperature, pressure)
  • Product Type
  • Metasys Digital VAV Controller
  • Outputs
  • Up to 4 analog/digital outputs
  • Model Number
  • AS-VAV111-1
  • Controller Type
  • Standalone digital controller
  • Actuator Support
  • Compatible with series of electronic damper actuators
 

Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
 

Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller About

Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller


The Johnson Controls AS-VAV111-1 is a digital Variable Air Volume (VAV) controller used in commercial HVAC systems to regulate single-duct, fan-powered, and supply/exhaust air box configurations. It operates standalone or links to a Metasys network via an N2 bus.


Key Features


  • Network Integration: Communicates over an N2 bus for facility-wide control and smart sensor sharing.
  • Removable Plugs: Features removable 24 VAC power and N2 communication plugs for easy swapping without cutting other wires.
  • Built-in Library: Includes a pre-tested program library to simplify setup without heavy custom coding.
  • Status LED: Provides a clear visual indicator light for fast system checks and troubleshooting




Precision Control for Reliable HVAC Performance

Designed to deliver consistent comfort and energy efficiency, the AS-VAV111-1 controller expertly manages variable air volume systems in demanding environments. Its digital control processing ensures swift, accurate responses to changing air flow requirements, while compatibility with various sensors and actuators enhances system flexibility.


Versatile Input and Output Capabilities

With the capacity to handle up to 8 universal inputs and 4 analog or digital outputs, this controller supports seamless integration of temperature, pressure, and other sensors. This versatility facilitates robust monitoring and fine-tuned regulation, adapting to the specific needs of each HVAC zone.

FAQ's of Johnson Controls AS-VAV111-1 Metasys Digital Variable Air Volume (VAV) Controller:


Q: How do I connect sensors and actuators to the AS-VAV111-1 VAV Controller?

A: The AS-VAV111-1 controller offers up to 8 universal inputs (supporting analog and digital sensors such as temperature or pressure) and 4 outputs for controlling compatible actuators. Simply follow the wiring diagrams in the installation manual and use the designated terminals for fast, secure connections.

Q: What types of HVAC applications is the AS-VAV111-1 suitable for?

A: This controller is specifically designed for variable air volume (VAV) control in HVAC systems, making it ideal for use in commercial, industrial, and institutional buildings where air flow modulation is required for comfort and energy efficiency.

Q: When should I use the onboard status LEDs?

A: The onboard status LEDs provide instant visual feedback on power and communication status. Use them during installation, troubleshooting, or routine maintenance to quickly verify proper operation or diagnose connectivity issues.

Q: Where should I mount the AS-VAV111-1 controller?

A: This open-style controller is intended for mounting in control panels or on DIN rails within indoor environments. Ensure placement is within the specified operating temperature and humidity ranges and is protected from dust, moisture, and direct exposure to harsh conditions.

Q: What is the process for integrating the controller into a Metasys N2 Bus network?

A: To connect the controller, wire it into the Metasys N2 Bus network as outlined in the product documentation. Assign the appropriate network address, then configure inputs, outputs, and parameters using Metasys-compatible software for seamless integration and system operation.

Q: How does the AS-VAV111-1 VAV Controller benefit HVAC system performance?

A: By precisely controlling air distribution and integrating with a range of sensors and actuators, this digital controller enhances comfort, optimizes energy use, and enables advanced monitoring-resulting in reliable and efficient HVAC system operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



arrow